Powered by Permasure®; Simple to use toxicity modeller app offering instant safe-use times accounting for temperature and chemical toxicity for over 4000 chemicals.
Multi-layer, high barrier fabric for protection against a wide range of hazardous liquid and gaseous chemicals. Yet very soft and flexible material for enhanced comfort. Fabric weight 365gsm.INT640W code; front entry / wide vision visor option.Superior design featuring double-taped seams (inside & out). Two-layer visor; (inner teflon and outer PVC layers) with unique etched seam-sealing technology for high chemical barrier. Two layer chemical glove system: inner chemical glove with outer barrier 27mil butyl glove. Tested against a full range of chemical warfare agents for anti-terror and civil defence operations. Two rear mounted exhaust valves. Attached sock boot with boot overflaps. Every Interceptor suit is gas-tight tested before leaving the factory. Pressure test kits are available separately.
Interceptor® Plus Physical Properties
Physical Property | Test Method | Units | Test Results |
---|---|---|---|
Abrasion Resistance | EN 530 | Cycles | >2000 / Class 2 |
Flex Cracking | EN 7854 | Cycles | >1000 / Class 1 |
Flex Cracking at -30C | EN 7854 | Cycles | >200 / Class 2 |
Trapezoidal Tear – cd | ISO 9073 | Newtons | 220N / Class 6 |
Trapezoidal Tear – md | ISO 9073 | Newtons | 246N / Class 6 |
Tensile Strength – cd | EN 13934 | Newtons | 396N / Class 4 |
Tensile Strength – md | EN 13934 | Newtons | 630N / Class 5 |
Puncture Resistance | EN 863 | Newtons | 43.6N / Class 2 |
Seam Strength | EN 13935 | Newtons | 655N / Class 6 |
Interceptor® Plus Permeation Data
Challenge Chemical | CAS Number | Physical State | Normalized Breakthrough Time |
---|---|---|---|
1,3-Butadiene | 106-99-0 | Liquid | >480 |
2,2,2-Trichloroethanol | 115-20-8 | Liquid | >480 |
2,3 Dichloro- 1Propene | 78-88-6 | Liquid | >480 |
2,4-Dichlorophenol | 120-83-2 | Liquid | >480 |
2,4-dichlorophenoxy Acetic Acid | 94-75-7 | Liquid | >480 |
4-Bromofluorobenzene | 460-00-4 | Liquid | >480 |
Acetic Acid | 64-19-7 | Liquid | >480 |
Acetone | 67-64-1 | Liquid | >480 |
Acetonitrile | 75-05-8 | Liquid | >480 |
Acetyl Chloridein | 75-36-5 | Liquid | >480 |
Acrolein | 107-02-8 | Liquid | >480 |
Acrylic Acid | 79-10-7 | Liquid | >480 |
Acrylonitrile | 107-13-1 | Liquid | >480 |
Allyl Chloride | 107-05-1 | Liquid | >480 |
Ammonia | 7664-41-7 | Liquid | >480 |
Ammonium Fluoride | 12125-01-8 | Liquid | >480 |
Bromine | 7726-95-6 | Liquid | 98 |
Carbon Disulfide | 75-15-0 | Liquid | >480 |
Chlorine | 7782-50-5 | Gas | >480 |
Dichloromethane | 75-09-2 | Liquid | >480 |
Diethylamine | 109-89-7 | Liquid | >480 |
Dimethylformamide | 68-12-2 | Liquid | >480 |
Ethyl Acetate | 141-78-6 | Liquid | >480 |
Ethylene Oxide | 75-21-8 | Gas | >480 |
Hexane | 110-54-3 | Liquid | >480 |
Hydrofluoric Acid | 7664-39-3 | Liquid | >480 |
Hydrogen Chloride | 7647-01-0 | Gas | >480 |
Hydrogen Fluoride | 7664-39-3 | Gas | >480 |
Methanol | 67-56-1 | Liquid | >480 |
Methyl Chloride | 74-87-3 | Gas | >480 |
Nitrobenzene | 98-95-3 | Liquid | >480 |
Phosphorus Pentachloride | 10026-13-8 | Liquid | >480 |
Sodium Hydroxide | 1310-73-2 | Liquid | >480 |
Sulfuric Acid | 7664-93-9 | Liquid | >480 |
Sulphur Dioxide | 7446-09-5 | Gas | >480 |
Sulphuryl Chloride | 7791-25-5 | Liquid | >480 |
Tetrachloroethylene | 127-18-4 | Liquid | >480 |
Tetrahydrofuran | 109-99-9 | Liquid | >480 |
Thionyl Chloride | 7719-09-7 | Liquid | 97 |
Toluene | 108-88-3 | Liquid | >480 |
Vinyl Chloride | 75-01-4 | Liquid | >480 |
PCB (Transformer Oil) | PCB | Liquid | >480 |
Carbon Tetrachloride | 56-23-5 | Liquid | >480 |
Cresol | 95-48-7 | Liquid | >480 |
Epichlorohydrin | 106-89-8 | Liquid | >480 |
Trimethyl Phosphate | 512-56-1 | Liquid | >480 |
NOTE: Permeation test data relates to “Normalised Breakthrough” which measures the time for permeation rate to reach a specific speed (In CE EN 6529 testing, 1.0?g/min/cm2 and in US testing, 0.1?g/min/cm2). This does not indicate when the chemical first breaks through the fabric and is not an indication of how long the suit can be safely used as the chemical may have permeated through the fabric before the Normalised Breakthrough time. This might be critical is cases of chemicals with high toxicity. For safe-use indications Safe-Use tines can be calculated manualy or refer to Permasure®.
Reviews