Specification for use of dense mesh vertical safety net

1. The safety net must be hung below the working position at height; When the height of the building exceeds 4 m, a safety net must be set up gradually with the wall, and then a fixed safety net must be set up every 4 M; The safety net must be set at the outer frame, bridge frame, upper and lower hole. The erection of safety net should be low inside and high outside, and the difference of expenditure is generally about 5 OCM; There is no fracture or bending of the supporting rod; The gap between the inner edge of the net and the wall should be less than 15cm; The distance between the lowest point of the net and the surface of the object below should be more than 3m. The diameter of the small end of the wooden pole shall not be less than 7cm, the diameter of the small end of the bamboo pole shall not be less than 8cm, and the spacing of the supporting poles shall not be more than 4m